MicroBurst® Miniature Jumpers for Broadband:

Micro-Miniature A06 Broadband Clocking Cable for 10G, 0.060 in. diameter, SSMP connectors.

Features:

Broadband

DC-50 GHz

Flex & Semi-Rigid



Applications:

Hi-Speed Products

Board Launch

10G and 40G

MicroBurst® Standard Connectors

SR034 SR047
SMP

Typical Insertion Loss
Max. Attenuation vs. Frequency (GHz) SR034 SR047 Connector Loss dB Straight Assy. SWR (x.xx:1)
dB/ft dB/m dB/ft dB/m
0.512 UHF 0.34 1.13 0.25 0.81 0.02 1.04:1
0.900 0.46 1.51 0.33 1.08 0.02 1.05:1
1.000 L 0.49 1.59 0.35 1.14 0.02
1.900 0.68 2.21 0.48 1.59 0.03 1.10:1
2.000 S 0.69 2.27 0.50 1.63 0.03
3.000 0.85 2.80 0.61 2.01 0.04
4.000 C 0.99 3.25 0.71 2.32 0.04 1.15:1
6.000 1.22 4.00 0.87 2.86 0.06
8.000 X 1.41 4.63 1.01 3.31 0.07 1.20:1
10.000 1.58 5.18 1.13 3.70 0.08 1.25:1
12.400 1.77 5.81 1.26 4.15 0.08
14.000 Ku 1.89 6.21 1.35 4.43 0.09 1.30:1
18.000 2.18 7.14 1.55 5.09 0.11
20.000 K 2.31 7.57 1.65 5.40 0.12
22.000 2.44 7.99 1.73 5.69 0.13
26.500 2.71 8.87 1.93 6.32 0.15 1.35:1
28.000 Ka 2.79 9.16 1.99 6.52 0.16 1.40:1
30.000 2.90 9.52 2.07 6.78 0.17
32.000 3.01 9.88 2.14 7.03 0.18
38.000 3.33 10.91 2.37 7.76 0.22 1.45:1
40.000 3.43 11.24 2.44 7.99 0.25
50.000 mm 3.91 12.81 2.77 9.10 0.32 1.50:1

MicroBurst® Electrical Data

SR034 SR047
Maximum Frequency Limited by Connector Interface
Impedance 50 ohm, nominal
Velocity of Propagation 69%, nominal
Time Delay 1.47 ns/ft (4.82 ns/m)
Capacitance 29.0 pF/ft (95.1 pF/m), nominal

MicroBurst® Mechanical Data

SR034 SR047
Outer Conductor Outer Diam. 0.034 in (0.86mm), nominal 0.047 in (1.19mm), nominal
Dielectric Outer Diam. 0.026 in (0.66mm), nominal 0.037 in (0.94mm), nominal
Center Conductor Outer Diam. 0.008 in (0.20mm), nominal 0.0113 in (0.29mm), nominal
Bend Radius .050 in (1.27mm), nominal
Operating Temperature -85 to 257 °F
(-65 to +125 °C)
-85 to 302 °F
(-65 to +150 °C)
Weight 0.0021 lbs/ft (0.0031 kg/m) 0.0038 lbs/ft (0.0057 kg/m)
Outer Conductor Sn Plated Copper Tube
Dielectric Solid PTFE
Inner Conductor Ag-plated CCS
Note: Other outer conductor plating available upon request. See Ordering Information.



For Attenuation & Power Derating Curves, Here.



Copyright © 2004 MegaPhase® LLC. All rights reserved.
Privacy Policy

MegaPhase LLC, 2098 West Main Street, Building 3, Stroudsburg, PA 18360-9526, USA
Phone: 1-877-MegaPhase / 570-424-8400 · Fax: 1-877-MegaFax / 570-424-6031