NextPhase™ Low Loss System Cable - Series 9:


Features:

Low Insertion Loss

High Performance

DC-50 GHz



Applications:

Communications

Radar

Uplink/Downlink

Airborne & Space



For Attenuation & Power Derating Curves, Here.

NextPhase™ Standard Connectors

912 916 919 930 945 950
2.4 mm to 50 GHz



2.92 mm (K) to 40 GHz



3.5 mm to 34 GHz


SMA to 26.5 GHz

7 mm to 18 GHz



Type N to 18 GHz
TNC

*Other connectors available on request.

Typical Insertion Loss
Max. Attenuation vs. Frequency (GHz) 912 dB/ft 916 dB/ft 919 dB/ft 930 dB/ft 945 dB/ft 950 dB/ft Conn. Loss dB SWR (x.xx:1)
0.450 VHF 0.10 0.08 0.05 0.03 0.02 0.02 0.01 1.05
0.900 UHF 0.15 0.11 0.07 0.05 0.03 0.03 0.02 1.12
1.000 L 0.16 0.12 0.08 0.06 0.04 0.04 0.02
2.000 S 0.23 0.17 0.11 0.08 0.06 0.05 0.03
3.000 0.28 0.21 0.14 0.09 0.07 0.06 0.04
6.000 C 0.41 0.31 0.21 0.14 0.11 0.10 0.06 1.25
12.000 Ku 0.60 0.45 0.30 0.21 0.16
0.08
18.000 0.75 0.56 0.38 0.27
0.11 1.35
24.000 K 0.89 0.66 0.45
0.14
30.000 Ka 1.02 0.75
0.16 1.45
40.000 1.20 0.89 0.25
50.000 1.35
0.28
Note: Insertion Loss & SWR increases with non-precision or angle connector types.

NextPhase™ Electrical Data

912 916 919 930 945 950
Maximum Frequency 50 GHz, nominal 40 GHz, nominal 28 GHz, nominal 18 GHz, nominal 12 GHz, nominal 10 GHz, nominal
Impedance 50 ohm, nominal
Velocity of Propagation 75.5%, nominal 76.0%, nominal 76.5%, nominal 77.0%, nominal 78.0%, nominal
Time Delay 1.35 Ns/ft 1.34 Ns/ft 1.33 Ns/ft 1.32 Ns/ft 1.31 Ns/ft
Capacitance 27.0 pF/ft, nominal 26.9 pF/ft, nominal 26.7 pF/ft, nominal 26.2 pF/ft, nominal 26.0 pF/ft, nominal
Inductance 67 nH/ft, nominal 66 nH/ft, nominal 62 nH/ft, nominal
Shielding Effectiveness <-90 dBc, minimum
Temperature Phase Stability 25 PPM
Voltage Breakdown >5 kW >7 kW >10 kW >15 kW >20 kW


NextPhase™ Mechanical Data

912 916 919 930 945 950
Jacketed Outer Diam. 0.126 inches, nominal 0.160 inches, nominal 0.190 inches, nominal 0.305 inches, nominal 0.450 inches, nominal 0.500 inches, nominal
Jacket Type FEP
Bend Radius 0.600 inches, nominal 0.900 inches, nominal 1.100 inches, nominal 1.800 inches, nominal 2.50 inches, nominal 2.750 inches, nominal
Operating Temperature -65 to 200°C
Unjacketed Wt. 0.02 lbs/ft 0.04 lbs/ft 0.05 lbs/ft 0.09 lbs/ft 0.20 lbs/ft 0.24 lbs/ft
Outer Conductor Flat Braid/Foil/Braid
Dielectric PTFE Tape
Inner Conductor Solid Ag-plated Copper Stranded Ag-plated Copper
Maximum Assembly Length 150 ft 150 ft 150 ft 150 ft 150 ft 150 ft
Flex Rating
Highest - 5.0
5.0 5.0 4.0 3.0 3.0 2.5